# Telephone Entry System Remote Programmer for Android
[![License](https://img.shields.io/badge/License-Apache%202.0-blue.svg)](https://opensource.org/licenses/Apache-2.0)
[![TES Remote Programmer](images/github_graphic.png)](http://mobile.thauvin.net/android/)
Program your Telephone Entry System remotely (off-site) using your phone.
Most Telephone Entry Systems can be programmed from the front keypad or remotely from an off-premise location using any touch-tone phone. TES Remote Programmer streamlines the often cumbersome remote programming process by providing data entry screens and automated dial-in options.
By default, TES Remote Programmer is configured to work with the [DoorKing (DKS) 1802 and 1802-EPD](http://www.doorking.com/telephone/1802-entry-system) systems, additional [configurations](#configurations) can be created for most systems supporting remote programming.
## Usage
![Main Activity](images/screenshots/main_activity_framed_small.png)
In the main activity screen enter the entry system's phone number and master code, then select one the programming options.
![Programming Activity](images/screenshots/add_phone_number_framed_small.png)
In the programming activity screen fill out the fields and click the ![Dial](images/call_fab.png) floating button (if available) to dial the programming in or the ![Dial](images/dialpad_fab.png) floating button to scroll through the manual (keypad) steps.
## Configurations
![Configurations](images/screenshots/configurations_framed_small.png)
To switch configuration, choose `Configurations` under the toolbar menu and select the desired configured.
To import a new configuration, select `Import` in the _Configurations_ dialog.
### New Configurations
Custom configurations can be created using [JSON](http://www.json.org/).
[View Example](app/src/main/res/raw/dks_1802_epd.json)
#### Parameters
Parameters define the configuration's global settings.
```json
"params": {
"name": "DKS 1802-EPD",
"star": "*",
"hash": "#",
"end": "0 + #",
"size": 4
}
```
| Parameter | Description | Required |
|:-----------|:-------------------------------------------------------------------------------------------------|:---------|
|`name` | The configuration name. | Yes |
|`star` | The key used to start, acknowledge or terminate programming steps. Most systems use the `*` key. | Yes |
|`hash` | They key used to in place of numbers when applicable. Most system use the `#` key | No |
|`end` | The end programming manual sequence. For example DoorKing uses `0` and `#` pressed together. | No |
|`size` | The size (number of digits) of the master code. Most systems use 4 or 5. | Yes |
### Options
Options define the data used to create programming activity screens in the app.
For example, the system's manual would list the steps to _Programming 7-digit Phone Numbers_ as something like:
1. Press *01 and enter Master Code.
2. Enter a Directory Code then press *.
3. Enter a 7-digit Phone Number then press *.
4. Press 0# TOGETHER when finished.
which would translate into:
```json
"opts": [
{
"title": "Add 7-digit Phone Number",
"fields": [
{
"hint": "Directory Code",
"size": 3
},
{
"hint": "Phone Number",
"size": 7,
"hash": true
}
],
"dtmf": "*01[MASTER],[FIELD:1]*,[FIELD:2]*"
}
]
```
| Elements | Description |
|:---------|:-----------------------------------------------------------------------------------------|
|`title` | The title of the option. |
|`fields` | See [Fields](#fields) |
|`dtmf` | See [DTMF](#dtmf) |
|`nodial` | Indicate thar remote programming is not available. Steps must be executed at the keypad. |
All are required, except `nodial`
#### Fields
```json
"fields": [
{
"hint": "Directory Code",
"size": 3
},
{
"hint": "Phone Number",
"size": 7,
"hash": true
}
]
```
Fields represent the data entry text fields on option screens.
| Element | Description | Required |
|:--------|:--------------------------------------------------------------------------------------------------|:---------|
|`hint` | Set the hint/label of the field. | Yes |
|`size` | Set the required size of the field. | Yes |
|`min` | Set the minimum value of a numeric field. | No |
|`max` | Set the maximum value of a numeric field. | No |
|`alpha` | Set to `true` if the field is alphanumeric. | No |
|`hash` | Set to `true` if the field accept the [Parameters](#parameters) `hash` value in place of a digit. | No |
#### DTMF
```json
"dtmf": "*01[MASTER],[FIELD:1]*,[FIELD:2]*"
```
DTMF represent the dialing sequence for the programming steps. A comma (`,`) can be used to specify a pause in the dialing sequence.
The following markers will be substituted by their actual values upon dialing.
| Marker | Description |
|:-----------|:------------------------------------------------------------------------------|
|`[MASTER]` | Substituted with the Master Code |
|`[FIELD:X]` | Substituted with the field's value, where X is the field number in the array. |
#### Validation
Imported configurations will be validated. While the validation is not perfect, it should be good enough to spot most syntax errors.
Please sure to use a JSON editor to make creating configurations a whole lot easier.
When in doubt be sure to look at the [default configuration](app/src/main/res/raw/dks_1802_epd.json).